Technical Data
Property | Test method | Standard Performance | Typical Performance |
---|---|---|---|
Tensile strength(MPa) | ASTM D 2671 | ≥ 10.4 | 11.5 |
Elongation(%) | ASTM D 2671 | ≥ 300 | 450 |
Tensile strength after aging(MPa) | UL224 158 ℃*168h | ≥ 7.3 | 8.5 |
Elongation after aging (%) | UL224 158 ℃*168h | ≥ 200 | 350 |
Dielectric strength(kV/mm) | IEC 60243 | ≥ 15 | 17.5 |
Volume resistivity( Ω.cm) | IEC 60093 | ≥ 1*1014 | 2.5* 1014 |
Property | Test method | Standard Performance |
---|---|---|
Water Absorption | ASTM D 570 | < 0.2% |
Softening Point(℃) | ASTM E 28 | 95 |
Strength of pearing (PE) | ASTM D 1000/td> | 120N/25mm |
Strength of pearing (AL) | ASTM D 1000/td> | 80N/25mm |